Diaphragm Smart Meter
To Connect x To Spread" Microcomputer S Meter

This diaphragm-type smart meter is designed to create a variety of "To Connect x To Spread" worlds in anticipation of the IoT society. A built-in wireless communication terminal can be installed under the counter.
Features
Built-in LTE-M communication module

Additional Functions
Load survey and pressure value acquisition and retention functions have been added.
Weighing and Compactness
The weight has been reduced from approximately 2.3 kg*1 to approximately 2 kg, making it lighter and more compact, and further pursuing user-friendliness.
Time Reduction
The time required to confirm the return leakage has been significantly reduced from approx. 50 sec. in the previous version*1to approx. 17 sec.
The time required to check for flow-type small leaks has been significantly reduced from approx. 45 min. in the previous version*1 to approx. 15 min.
Clear meter status
The shutdown event is indicated in kanji characters, and the pressure value is also indicated numerically, making the meter status clearer.
*1:Compared with our microcomputer meter S (
™) for LP gas.
Continuous use time over shutoff
Specifications
- Model
- SK25MT1SNL (90 mm between inlet and outlet)/SK25MT1SBL (130mm)
- Maximum flow rate
- 2.5㎥/h
- Metering chamber volume
- 0.5L/rev.
- Normal operating pressure
- 2.8±0.5kPa
- Maximum operating pressure
- 10kPa
- Maximum indicated volume
- 9999.999㎥
- Minimum scale
- 0.2L
- Pressure loss*1
- Max. 130 Pa
- Shutoff function
- Total/increased flow shutoff, time-of-use shutoff, test shutoff, seismic isolator actuation shutoff,
pressure drop shutoff, external sensor shutoff (including gas alarm),
Low battery voltage shutoff, expiration of verification period shutoff, meter error shutoff
- Warning functions
- Low leakage warning detected by flow, Low leakage warning detected by pressure, Adjusted pressure abnormality warning,
Closed pressure abnormality warning, Shut-off abnormality warning, Low battery voltage warning,
Expiration of validation period warning, Meter error warning
- Display function
- Security display, shutoff display, alarm display, container reset
- Function setting method
- Simple setting by message setter or center setting
- Recovery safety confirmation time
- Approx. 17 sec.
- Pulse output
(Output unit*2/ ON width - 1L/p (standard)/200ms±50,
10L/p, 100L/p, 1000L/p / (Option when ordering) 500ms±50
- Maximum rated voltage/current/
Internal resistance / Number of outputs - 24V / 20mA / 51Ω±10Ω / 2 wires and 2 outputs
- Power source
- Lithium battery (10 years)
- Operating environment temperature
- -30~+60℃
- Standard coating color
- Light gray (Munsell symbol 5Y 7.5/1 or equivalent)
- Weight
- Approx. 2.0kg
*1: Actual LPG flow rate (at pressure loss of 150 Pa): Model SK25MT1SNL→4.8kg/h, Model SK25MT1SBL→4.6kg/h
*2: Pulse output unit cannot be changed after shipment.
Exterior view
security display

The security display of the Microcomputer Meter S is shown on a liquid crystal display (LCD).

Resume operation when the gas meter is shut off
*Check for gas smell as gas leakage may be suspected. If you smell gas, do not operate the meter to turn it back on, but contact the gas supplier immediately.
How to resest the meter (Japanese)
How to reset the meter (English)