Electronic Water Meter

E series: Screw-in type
(Model EKDA/ EKDL/ EKDS)

Model EKDA13 Model EKDL13 Model EKDA20 Model EKDS40
  • 13mm
  • 20mm
  • 25mm
  • 30mm
  • 40mm
  • 50mm
  • Measuring method
    vane wheel type water meter
  • Diameter
    13~50mm
  • JIS compliant
  • Pulse output
  • Mounting posture
    Horizontal
  • Measuring range
    R100
  • Threaded type
Model EKDA13 is L=100mm
Model EKDL13 is L=165mm
Model EKDA25 is L=210mm
Model EKDL25 is L=225mm

*L dimensions are different between Model EKDA and Model EKDL.

Standard Features
  • Load survey
  • Instantaneous flow rate display
  • Leakage warning
  • Excessive flow warning
  • Reverse flow detection
  • Low battery voltage warning
  • False count prevention
Option
  • Water non-use detection
  • Excess flow detection
  • Timely meter reading
  • Terminal call

E Series: Approximate usage of screw-in type (Models EKDA/ EKDL/ EKDS) ㎥ [( ): ㎥/h].

Specifications

Click to enlarge

E Series: Performance curve diagram for screw-in type (Model EKDA/ EKDL/ EKDS)

E series: Flange type
(Model EFDW/EFDT/ EKDW)

Model EFDW50 Model EFDT50
  • 50mm
  • 65mm
  • 75mm
  • 100mm
Model EKDW50
  • For water utility
  • 50mm
  • 75mm
  • 100mm
  • Measuring method
    vane wheel type water meter
  • Diameter
    50~100mm
  • JIS compliant
  • Telegram
    Pulse output
  • Mounting posture
    Horizontal
  • Measuring range
    R100
  • Flange type
Standard function
  • Load survey
  • Instantaneous flow rate display
  • Leakage warning
  • False count prevention
Option
  • Leakage warning
  • Excessive flow warning
  • Reverse flow detection
  • Water non-use detection
  • Excess flow detection
  • Regular meter reading
  • Terminal call

E Series: Approximate usage of flange type (Models EFDW/EFDT/ EKDW) ㎥ [( ): ㎥/h].

Specifications

Click to enlarge

E Series: Performance curve diagram for flange type (Model EFDW/EFDT/ EKDW)

Separate measurement indicator (for E series)

Model eKICL

[Bi-Measurement Indicator]

Totalized value is displayed during normal operation.

  • ・Totalized value is updated every 12 hours by telegram communication.
  • ・Counting by input pulse in normal operation

Instantaneous flow rate value can be checked by magnet operation
Displays various warnings of the water meter
Pulse and telegram signals can be re-emitted
Operates for 8 years without external power supply

Centralized Meter Reading Panel KILVIS

Model KILVIS-HA (indoor specification) Model KILVIS-HA (outdoor specification)

[Centralized meter reading panel] main unit
[Centralized meter reading panel] terminal

The centralized meter reading panel "Model KILVIS-HA" is a device for centralized meter reading in tenant buildings and condominiums.
There are two types of connection methods: the star method, in which the meter is directly connected to the meter reading board, and the bus method, in which the meter is connected via a terminal device.
The meter is a meter with an 8-bit communication function. A PC can also be connected for data collection.

Centralized Meter Reading Board (Battery-powered, star system)

Model RSJ (indoor specification)

This centralized meter reading panel (indoor specification) for small-scale housing complexes is easy to operate. When the meter reading switch is pressed, communication is established with the meter and the pointer value is displayed.
The electronic water meter alarm status can be checked, the instantaneous flow rate value displayed, and the alarm reset. Easy wiring, installation in a small space, and no power supply required.

*To maintain electrical performance, replacement is recommended after 16 years. The built-in battery board should be replaced 8 years after installation.
*Automatic meter reading is not possible due to manual operation.

Mini counter (for E series)

Model eMIC2

This is a bi-metering mini-counter for electronic water meters with 8-bit communication function. It communicates with the meter every 12 hours and displays meter readings and various alarms as needed.

Specification