Diaphragm Smart Meter K-SMα

Diaphragm Smart Meter
To Connect x To Spread" Microcomputer S Meter

K-SMa

This diaphragm-type smart meter is designed to create a variety of "To Connect x To Spread" worlds in anticipation of the IoT society. A built-in wireless communication terminal can be installed under the counter.

Features

Built-in LTE-M communication module

Built-in LTE-M communication module

Additional Functions

Load survey and pressure value acquisition and retention functions have been added.

Weighing and Compactness

The weight has been reduced from approximately 2.3 kg*1 to approximately 2 kg, making it lighter and more compact, and further pursuing user-friendliness.

Time Reduction

The time required to confirm the return leakage has been significantly reduced from approx. 50 sec. in the previous version*1to approx. 17 sec.
The time required to check for flow-type small leaks has been significantly reduced from approx. 45 min. in the previous version*1 to approx. 15 min.

Clear meter status

The shutdown event is indicated in kanji characters, and the pressure value is also indicated numerically, making the meter status clearer.

*1:Compared with our microcomputer meter S (KCUBE™) for LP gas.

Continuous use time over shutoff

Specifications

Click to enlarge

Specifications

Model
SK25MT1SNL (90 mm between inlet and outlet)/SK25MT1SBL (130mm)
Maximum flow rate
2.5㎥/h
Metering chamber volume
0.5L/rev.
Normal operating pressure
2.8±0.5kPa
Maximum operating pressure
10kPa
Maximum indicated volume
9999.999㎥
Minimum scale
0.2L
Pressure loss*1
Max. 130 Pa
Shutoff function
Total/increased flow shutoff, time-of-use shutoff, test shutoff, seismic isolator actuation shutoff,
pressure drop shutoff, external sensor shutoff (including gas alarm),
Low battery voltage shutoff, expiration of verification period shutoff, meter error shutoff
Warning functions
Low leakage warning detected by flow, Low leakage warning detected by pressure, Adjusted pressure abnormality warning,
Closed pressure abnormality warning, Shut-off abnormality warning, Low battery voltage warning,
Expiration of validation period warning, Meter error warning
Display function
Security display, shutoff display, alarm display, container reset
Function setting method
Simple setting by message setter or center setting
Recovery safety confirmation time
Approx. 17 sec.
Pulse output
(Output unit*2/ ON width
1L/p (standard)/200ms±50,
10L/p, 100L/p, 1000L/p / (Option when ordering) 500ms±50
Maximum rated voltage/current/
Internal resistance / Number of outputs
24V / 20mA / 51Ω±10Ω / 2 wires and 2 outputs
Power source
Lithium battery (10 years)
Operating environment temperature
-30~+60℃
Standard coating color
Light gray (Munsell symbol 5Y 7.5/1 or equivalent)
Weight
Approx. 2.0kg

*1: Actual LPG flow rate (at pressure loss of 150 Pa): Model SK25MT1SNL→4.8kg/h, Model SK25MT1SBL→4.6kg/h
*2: Pulse output unit cannot be changed after shipment.

Exterior view

security display

security display

The security display of the Microcomputer Meter S is shown on a liquid crystal display (LCD).

Warning Indication・Shutdown Indication

Resume operation when the gas meter is shut off

*Check for gas smell as gas leakage may be suspected. If you smell gas, do not operate the meter to turn it back on, but contact the gas supplier immediately.

How to resest the meter (Japanese)

How to reset the meter (English)

How to reset the meter (Chinese)

How to reset the meter
(português)  

Specification