Electromagnetic water meter MagneW™ FLEX+Made by Azbil Corporation
Type MGT20□/22□
External Power Supply Type Water MeterWater meters powered by an external power supply for water consumption transactions and billing purposes for industrial water, drinking water, etc. as stipulated in the Measurement Law.- (1) This water meter is compliant with the Japanese Measurement Law in accordance with the JISB8570 standard from April 2011.
- (2) In addition to pulse output for verification, it also supports analog output for management purposes.
-
Electromagnetic flowmeterGeneral Type ConverterMagneW™ FLEX+Made by Azbil Corporation
Type MGG10C
4-wiregeneral-purposeTransducers to be used in combination with MagneW™ FLEX+ series detectors- (1) Transducer operation by easy-to-operate infrared touch sensor for improved safety in the field.
- (2) Error logs and product information are recorded in the transducer's internal nonvolatile memory and can be recalled and checked at any time.
-
Electromagnetic FlowmeterGeneral type / Submersible type DetectorMagneW™ FLEX+Made by Azbil Corporation
Type MGG11□/12□
4-wiregeneral type / submersible typeFor flow management/control of chemicals, chemical solutions, corrosive liquids, aqueous solutions, water, etc.- (1) Applicable to a wide range of flow rates with bore diameters from 2.5 mm to 1100 mm (general type) and 15 to 600 mm (submersible type).
- (2) In addition to our face to face detectors, we also offer replaceable face to face detectors to replace electromagnetic flowmeters made by many other manufacturers.
- (3) Mirror-finished PFA linings are available as standard for bore diameters from 2.5 mm to 600 mm. This contributes to reducing the frequency of cleaning and other maintenance for highly adherent fluids.
-
2-wire type electromagnetic flowmeterGeneral typeMagneW™ Neo+Made by Azbil Corporation
Type MTG11□
2-wiregeneral-purposeFor flow management and control of chemicals, chemical solutions, corrosive liquids, water, etc.- (1) 24 VDC and 2-wire instrumentation similar to differential pressure transmitter.
- (2) This 2-wire electromagnetic flowmeter is compatible with both integrated and separate types.
- (3) Power consumption is less than 0.1W, contributing to energy saving.
-
Submersible Electromagnetic Flowmeter MagneW™ 3000 FLEX+Made by Azbil Corporation
Type NNK140/941
4-wiretotalized volume meter for wastewaterFor drainage flow control in permanently submerged, open waterways and culverts, or for use in compliance with the Total Effluent Volume Regulation stipulated in the Measurement Law.- (1) It is applicable as an integrated volumetric flowmeter for wastewater as stipulated in the Measurement Law, in compliance with the Total Volume of Wastewater Regulation.
- (2) This electromagnetic flowmeter can be installed in open waterways and is a highly accurate volumetric flowmeter that uses the principle of a small orifice.
-
Electromagnetic Totalizing CalorimeterMade by Azbil Corporation
Type MCJ20A
4-wire Type Totalizing CalorimeterUses for billing hot water usage according to the amount of heat used per tenant in building air conditioning as stipulated in the Measurement Law- (1) This is a totalizing calorimeter specified in the Measurement Law for measuring and billing the amount of heat used in building air-conditioning.
- (2) JIS B7550:2017 compliant
Bore diameters of 25 mm and 40 mm are available for tenant billing.
-
Calibration Int
Top-level flowmeter production and calibration facilities registered under the JCSS Measurement Law Calibration Service Provider Registration System
・Piping with a maximum upstream straight pipe length of 50D
Maximum bore size up to 1200 mm Equipped with 9 measuring instruments based on the mass method, with a production capacity of 30,000 units.

・Dedicated equipment for on-site inspection
The bore diameter can be up to 200 mm. We have prepared equipment that allows customers to check with confidence.

・Calibration equipment (tank)
Tank with a height of 35m. The tank is an overflow elevated tank, which allows for a constant water head difference.
Azbil Kyoto Corporation is registered as a calibration service provider of JCSS (Japan Calibration Service System, a registration system for calibration service providers under the Measurement Law) for "flow rate and velocity (liquid flowmeters)" and is capable of general and JCSS calibration as well as flowmeter production.
JCSS is a calibration service registration system introduced to ensure the reliability of high-precision measurement and quality control with the enforcement of the revised Measurement Law in 1993.
While general calibration can be performed by self-declaration, JCSS, which is accredited by the National Institute of Technology and Evaluation (NITE), is a system in which the quality system, calibration methods, uncertainty estimation, and facilities of a business operator are assessed for appropriateness in performing calibration, and the quality system is operated as specified. The JCSS is registered after examining whether the operator's quality system, calibration methods, uncertainty estimates, facilities, etc., are appropriate for performing calibration, and whether the quality system is being operated as specified, which enables the issuance of calibration certificates bearing the JCSS mark.
Azbil Kyoto Corporation's registration as a calibration service provider for "velocity and flow (liquid flowmeters)" covers a range of 2.5 to 1200 mm in bore size and 0.002 to 5090 m3/h, with a maximum measurement capability of 0.1%. This is the widest range of bore diameters and flow rates in Japan and maintains the top level of calibration and measurement capability. In addition to being registered as a calibration service provider, Azbil Kyoto Co., Ltd. is also accredited as a certified service provider for the Global Mutual Recognition Arrangement (MRA)*.*International MRA (Mutual Recognition Arrangement)
MRA refers to multilateral mutual recognition. International Mutual Recognition means mutual evaluation (peer review) among participating accreditation bodies, and the operation of accreditation bodies is based on the international standard ISO/IEC 17011, and the use of ISO/IEC 17025 as an accreditation standard is evaluated. ILAC (International Laboratory Accreditation Conference)/APLAC (Asia Pacific Laboratory Accreditation Cooperation The mutual recognition of accreditation organizations that meet international standards has been recognized by the ILAC (International Laboratory Accreditation Conference) and APLAC (Asia Pacific Laboratory Accreditation Cooperation).
*Water meters (including models MGB12A and MGT) cannot be re-calibrated.