- Measuring method
vane wheel type water meter - Diameter
13~100mm - JIS compliant
- Telegram
Pulse output - Mounting posture
Horizontal - Measuring range
R100
・The meter is equipped with a telegram communication function for more reliable meter reading. Pulse output can be simultaneously output for various situations.
・The meter is also capable of various alarm detection functions and data accumulation by load survey.
- 13mm
- 20mm
- 25mm
- 30mm
- 40mm
- 50mm
- 65mm
- 75mm
- 100mm
Feature
Click to enlarge
List of Functions
Click to enlarge
Display section
Function-packed display
- Large digits are m3 digits
- Medium size is L digits
- Minimum size is 0.1L digits (13 to 50 mm)
- Various warning indications
・Excessive flow rate
・Leakage
・Battery voltage
・Reverse flow - Pilot display showing water flow status
- Instantaneous flow rate can be switched by magnet operation.
Click to enlarge
Symbols for systematized measuring instruments
R: If the instrument has telegram communication, R is indicated.
R3413: If the instrument has pulse output function, a specific number is indicated after the R symbol.
- Meaning of each number:
The first "34" indicates the pulse signal method, which may vary depending on the manufacturer.
The second half "13" indicates the pulse rate.
Output Specifications
8-bit telegrams and pulses can be output.
Pulse rate is selectable.
- The 8-bit telegram output is used for automatic meter reading systems using telephone lines and wireless meter reading systems.
- The factory standard pulse setting is a no-unit pulse that directly outputs the impeller rotation. When ordering, one of the unit pulses (4 types) shown below can be selected and set at the factory.
●Pulse output specifications
Click to enlarge
Wiring Method
- How to wire with Remoter measurement indicator Model eKICL
(Only for battery-powered electromagnetic water meters and electronic water meters)
Click to enlarge
Power source
Battery operated for 9 years
Lithium battery (9-year battery life) not replaceable
Request
The 8-bit multi-functional electronic water meter is composed of precision electronic equipment.
For long-term use, please keep the meter out of direct sunlight and use it in an appropriate ambient temperature.
Remote measurement indicator (for electronic water meters)

[Bi-Measuring Indicator]
Totalized value is displayed during normal operation.
- ・Totalized value is updated every 12 hours by telegram communication.
- ・Counting by input pulse in normal operation
Instantaneous flow rate value can be checked by magnet operation
Displays various warnings of the water meter
Pulse and telegram signals can be re-emitted
Operates for 8 years without external power supply
Centralized Meter Reading Panel KILVIS

[Centralized meter reading panel] main unit
[Centralized meter reading panel] terminal
The centralized meter reading panel "Model KILVIS-HA" is a device for centralized meter reading in tenant buildings and condominiums.
There are two types of connection methods: the star method, in which the meter is directly connected to the meter reading board, and the bus method, in which the meter is connected via a terminal device.
The meter is a meter with an 8-bit communication function. A PC can also be connected for data collection.
Centralized Meter Reading Board (Battery-powered, star system)

This centralized meter reading panel (indoor specification) for small-scale housing complexes is easy to operate. When the meter reading switch is pressed, communication is established with the meter and the pointer value is displayed.
The electronic water meter alarm status can be checked, the instantaneous flow rate value displayed, and the alarm reset.
Easy wiring, installation in a small space, and no power supply required.
* To maintain electrical performance, replacement is recommended after 16 years. In addition, the built-in battery board should be replaced 8 years after installation.
*Automatic meter reading is not possible due to manual operation.
Mini Counter (for electronic water meter)

A bi-metering mini-counter for electronic water meters with 8-bit communication function. It communicates with the meter every 12 hours and displays meter readings and various alarms as needed.
Specifications, External drawing
[Tangential-flow-wheel type] Screwed type
![[Tangential-flow-wheel type] Screwed type](/asset/img/product/water/electronicmeter/detail_spec_photo01.jpg)
- Specifications (PDF)
-
Model :
- External view (PDF)
-
Model :
[Axial-flow wheel type] Screwed type
![[Tangential-flow-wheel type] Screw-in type](/asset/img/product/water/electronicmeter/detail_spec_photo02.jpg)
- Specifications (PDF)
-
Model :
- External view (PDF)
-
Model :
[Axial-flow wheel type] Flange type
![[Axial-flow wheel type] Flange type](/asset/img/product/water/electronicmeter/detail_spec_photo03.jpg)
- Specifications (PDF)
-
Model :
[Axial-flow wheel type] Flange type/Short type
![[Axial-flow wheel type] Flange type/Short type](/asset/img/product/water/electronicmeter/detail_spec_photo04.jpg)
- Specifications (PDF)
-
Model :