- 50mm
- 65mm
- 75mm
- 100mm
- 125mm
- 150mm
- 200mm

High Performance Battery Electromagnetic Water Meter
Battery operated for 9 years (valid for certification for 8 years)
Highly functional "Battery Electromagnetic" with backlight and display orientation
*Please prevent the following when using the product horizontally (△)
・Residual air in the piping.
・Air in the water flowing through the unit.
・Accumulation of foreign matter
MGB12A is designed for easy meter reading
Backlight for clear reading in the dark
When the lid is opened, the backlight illuminates for about 30 seconds for clear reading of the totalized value.

Display rotates 180 degrees for easy reading
When the display is facing the opposite direction depending on the mounting position, the display can be rotated with the lid closed to face the opposite direction.

Large LCD simultaneously displays totalized value and instantaneous flowrate
To make the totalized value easier to read, the LCD has been enlarged.
Also, by displaying the instantaneous flow rate at the same time, there is no need to switch between the two, making flow rate management easy.

Ideal for large flow rates!
Continuous use is possible at the rated maximum flow rate Q3
Continuous water flow is possible even at large capacities.
Monthly usage is approximately 18 times that of vane wheel type
Reliable design for long-term use!
Improved performance against foreign matter and submersion in water
No moving parts such as impellers are used in the construction, so there is no need to worry about durability or slow or immobility due to contamination by foreign objects.
IP68 submersible performance ensures safe use even in pits where water tends to accumulate.
Compact and lightweight for easy installation
Easy installation with 1/10 of the mass ratio
Much lighter than vane wheel type water meter.
Reduces the number of personnel and equipment required for installation!
No need to worry about mounting posture
Can be mounted in any direction
No moving parts such as horizontal, vertical, or diagonal, so it can be installed in any direction.
- ・The display is difficult to read because it is so close to the ceiling.
- ・Cannot install straight because other piping is in the way.
- ・Piping is vertical, so I want to install it to vertically.
*In the case of horizontal (△), please prevent the following - ・Residual air in the piping.
- ・Air should be mixed with the water in the pipe.
- ・Accumulation of foreign matter

The MGB12A can be used in a variety of situations.

For wastewater metrology of cooling towers
Specific measuring instrument
Resistant to foreign matter
Ideal for wastewater metrology that is prone to foreign matter
Submersible type Waterproof performance
Reliable even in outdoor installations exposed to rain and wind

For agricultural water flow management
Supports large flow rates
Continuous use at rated maximum flow rate is possible
Built-in battery operation
Ideal for use where no power source is available
Resistant to contamination by foreign matter
Ideal for metering fluids that are prone to contamination by foreign matter, etc.
Communication function
Supports centralized meter reading by wireless communication

For flow control of water for wells and snow removal
Specified measuring instruments
Ideal for usage rate transactions
Resistant to foreign matter
Ideal for measuring fluids that are prone to contamination by foreign matter
Built-in battery operation
Ideal for use where there is no power supply

For measuring water supply to ships and water trucks
Specific measuring instrument
Ideal for trading water supply charges
Built-in battery operation
Ideal for use where there is no power supply
Portable (mobile)
Safety and protection functions are also available.
⇒ See Portable Water Meter MGB-P for details

For water volume control of plant facilities and industrial water
Metering and compact design
Ideal for installation in narrow or elevated locations
Flexible mounting position
Can be mounted on vertical or diagonal pipes
Backlight function
safe meter reading in dark places
Communication function
Can be used for centralized monitoring and energy management

Compatible with all types of existing meter replacements
We offer a wide variety of replacement accessories for both older and non-existing meters
・Older vane wheel type meters
・Other manufacturer's water meters
⇒ See specifications page for details
Various display functions for peace of mind
Warning indication when something is wrong!
Warning indication for problems during use, such as backflow, excessive flow, and empty detection function when not full.
As a new function, we have added a communication display that appears when telegrams are communicated with the display unit, etc.

Various Applications
The communication function can be deployed in a variety of applications
・Remote measurement indicator
・Centralized meter reading panel
・Wireless meter reading, etc.
Please refer to Electronic Water Meter for application and communication specifications.

Download catalog
Specifications, External drawing
[Tangential-flow-vane wheel type] Union connection type
![[Tangential-flow-vane wheel type] Union connection type](/asset/img/product/water/batterymeter/mgb12a/chart26.jpg)
- Common documents (PDF)
- Specifications (PDF)
-
No output
- All diameter sizes(50~200) (0.08MB)
- MGB12A-50 (0.08MB)
- MGB12A-65 (0.08MB)
- MGB12A-75 (0.08MB)
- MGB12A-100 (0.08MB)
- MGB12A-125 (0.08MB)
- MGB12A-150 (0.08MB)
- MGB12A-200 (0.08MB)
Power output
- External view (PDF)
-
No output
- MGB12A-50 (0.08MB)
- MGB12A-65 (0.07MB)
- MGB12A-75 (0.07MB)
- MGB12A-100 (0.08MB)
- MGB12A-125 (0.08MB)
- MGB12A-150 (0.08MB)
- MGB12A-200 (0.08MB)
Power output