MGB12A

A battery-type electromagnetic meter with no moving parts and a large flow range
国土交通省公共建築工事標準仕様適合品 MGB12A
  • 50mm
  • 65mm
  • 75mm
  • 100mm
  • 125mm
  • 150mm
  • 200mm

High Performance Battery Electromagnetic Water Meter

Battery operated for 9 years (valid for certification for 8 years)
Highly functional "Battery Electromagnetic" with backlight and display orientation
*Please prevent the following when using the product horizontally (△)
・Residual air in the piping.
・Air in the water flowing through the unit.
・Accumulation of foreign matter

MGB12A is designed for easy meter reading

Backlight for clear reading in the dark

When the lid is opened, the backlight illuminates for about 30 seconds for clear reading of the totalized value.

Display rotates 180 degrees for easy reading

When the display is facing the opposite direction depending on the mounting position, the display can be rotated with the lid closed to face the opposite direction.

Large LCD simultaneously displays totalized value and instantaneous flowrate

To make the totalized value easier to read, the LCD has been enlarged.
Also, by displaying the instantaneous flow rate at the same time, there is no need to switch between the two, making flow rate management easy.

Simultaneous display of both totalized and instantaneous flow rates

Ideal for large flow rates!

Continuous use is possible at the rated maximum flow rate Q3

Continuous water flow is possible even at large capacities.
Monthly usage is approximately 18 times that of vane wheel type

Reliable design for long-term use!

Improved performance against foreign matter and submersion in water

No moving parts such as impellers are used in the construction, so there is no need to worry about durability or slow or immobility due to contamination by foreign objects.
IP68 submersible performance ensures safe use even in pits where water tends to accumulate.

No moving parts / IP68

Compact and lightweight for easy installation

Easy installation with 1/10 of the mass ratio

Much lighter than vane wheel type water meter.
Reduces the number of personnel and equipment required for installation!

No need to worry about mounting posture

Can be mounted in any direction

No moving parts such as horizontal, vertical, or diagonal, so it can be installed in any direction.

  • ・The display is difficult to read because it is so close to the ceiling.
  • ・Cannot install straight because other piping is in the way.
  • ・Piping is vertical, so I want to install it to vertically.
    *In the case of horizontal (△), please prevent the following
  • ・Residual air in the piping.
  • ・Air should be mixed with the water in the pipe.
  • ・Accumulation of foreign matter

*is OK as long as kept full of water.

The MGB12A can be used in a variety of situations.

For wastewater metrology of cooling towers

Specific measuring instrument

Resistant to foreign matter

Ideal for wastewater metrology that is prone to foreign matter

Submersible type Waterproof performance

Reliable even in outdoor installations exposed to rain and wind

For agricultural water flow management

Supports large flow rates

Continuous use at rated maximum flow rate is possible

Built-in battery operation

Ideal for use where no power source is available

Resistant to contamination by foreign matter

Ideal for metering fluids that are prone to contamination by foreign matter, etc.

Communication function

Supports centralized meter reading by wireless communication

For flow control of water for wells and snow removal

Specified measuring instruments

Ideal for usage rate transactions

Resistant to foreign matter

Ideal for measuring fluids that are prone to contamination by foreign matter

Built-in battery operation

Ideal for use where there is no power supply

For measuring water supply to ships and water trucks

Specific measuring instrument

Ideal for trading water supply charges

Built-in battery operation

Ideal for use where there is no power supply

Portable (mobile)

Safety and protection functions are also available.
⇒ See Portable Water Meter MGB-P for details

For water volume control of plant facilities and industrial water

Metering and compact design

Ideal for installation in narrow or elevated locations

Flexible mounting position

Can be mounted on vertical or diagonal pipes

Backlight function

safe meter reading in dark places

Communication function

Can be used for centralized monitoring and energy management

Compatible with all types of existing meter replacements

We offer a wide variety of replacement accessories for both older and non-existing meters
・Older vane wheel type meters
・Other manufacturer's water meters
⇒ See specifications page for details

Various display functions for peace of mind

Warning indication when something is wrong!

Warning indication for problems during use, such as backflow, excessive flow, and empty detection function when not full.
As a new function, we have added a communication display that appears when telegrams are communicated with the display unit, etc.

warning display

Various Applications

The communication function can be deployed in a variety of applications

・Remote measurement indicator
・Centralized meter reading panel
・Wireless meter reading, etc.
Please refer to Electronic Water Meter for application and communication specifications.

Output signal 8-bit telegram output Pulse output 100L/P (50 to 125mm) 1,000L/P (50 to 200mm) Output cable

Download catalog

Specifications, External drawing

[Tangential-flow-vane wheel type] Union connection type

Specification